G6 LEONARDO analyzer Specification

  • Features
  • High automation, modular design, real-time data, user-friendly interface
  • Max Height
  • 520 mm
  • Number of Specimens
  • 1-4 at a time
  • Specimen Size
  • 50 mm 50 mm, customizable
  • Accuracy
  • 0.01% (of reading)
  • Port Size
  • Standard 1/4
  • Operating Voltage
  • 220-240 V AC
  • Resolution
  • 0.001 cc/(m2dayatm)
  • Display Type
  • Touchscreen LCD
  • Humidity
  • 10% - 90% RH (non-condensing)
  • Mounting Type
  • Benchtop
  • Temperature
  • 5C - 45C
  • Gas Pressure
  • 0.15 - 0.5 MPa
  • Response Time
  • < 3 seconds
  • Measuring Range
  • 0.01 - 1000 cc/(m2dayatm)
  • Equipment Type
  • Gas Permeability Analyzer
  • Frequency
  • 50-60 Hz
  • Application
  • Measuring gas permeability of films and materials
  • Interface Type
  • USB, Ethernet
  • Power Supply
  • 230 V / 50-60 Hz
  • Test Range
  • 0.001 - 1.000 ml/min
  • Automation Grade
  • Automatic
  • Usage
  • Laboratory film analysis
  • Capacity
  • Single or batch testing
  • Machine Weight
  • 48 kg (approx.)
  • Test Speed
  • Up to 60 tests/hour
  • Test Width
  • Standard size, customizable as per requirement
  • Test Stroke
  • Up to 30 mm
  • Control Mode
  • Full automatic and manual control
  • Standards Compliance
  • ASTM D1434, ISO 15105-1
  • Color
  • White/Grey
  • Chamber Material
  • Stainless Steel
  • Memory Storage
  • Internal, Supports USB backup
  • Calibration
  • Automatic & Manual
  • Data Output
  • CSV, PDF
  • Software Support
  • PC software with remote monitoring
  • Safety Features
  • Overpressure protection, system diagnostics
 

G6 LEONARDO analyzer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 12 Units Per Month
  • Delivery Time
  • 2-10 Days
  • Main Domestic Market
  • All India
 

About G6 LEONARDO analyzer



Grab the opportunity to own the G6 LEONARDO analyzer, a rare and praiseworthy best-seller designed for elite laboratory film analysis. Engineered with a breathtaking stainless steel chamber and packed with automated features, it ensures precise measurement with an astounding accuracy of 0.01% and blazing-fast response time under 3 seconds. Benefit from its high automation, overpressure protection, and seamless compatibility with ASTM D1434 and ISO 15105-1 standards. The user-friendly touchscreen LCD and robust PC software support, including remote monitoring and USB backup, make it the top choice for advanced, reliable material testing. Get unmatched results every time!

Elite Features of the G6 LEONARDO Analyzer

Experience cutting-edge automation with the G6 LEONARDO analyzer, crafted from premium stainless steel for durability and safety. Its advanced system diagnostics and overpressure protection ensure reliable performance, while the modular, user-friendly design allows effortless operation. Frequently utilized by research labs, manufacturers, and quality control experts, the G6 LEONARDO delivers accurate, real-time data. Supporting both single and batch testing, it excels in demanding laboratory environments where precision and compliance are paramount.


Sample Policy and Quick Dispatch of G6 LEONARDO

Sample availability for the G6 LEONARDO analyzer can be handed over promptly upon request, adhering to a straightforward sample policy. Payment terms are designed to be flexible for easy transactions, ensuring smooth purchases for clients. Freight charges may apply depending on delivery location, but our quick dispatch system guarantees that product shipment is organized efficiently and without unnecessary delays. Rely on us for transparent processes and timely delivery, making your equipment acquisition effortless.


FAQ's of G6 LEONARDO analyzer:


Q: How does the G6 LEONARDO analyzer ensure measurement accuracy?

A: The G6 LEONARDO analyzer guarantees high accuracy through its advanced calibration options-both automatic and manual-and state-of-the-art sensors, enabling a resolution of 0.001 cc/(m2dayatm) and an accuracy of 0.01% of the reading.

Q: What safety features does the G6 LEONARDO provide during operation?

A: This analyzer includes overpressure protection and system diagnostics, actively safeguarding users and equipment while maintaining optimal and safe working conditions throughout the analysis process.

Q: When can I expect my G6 LEONARDO analyzer after purchase?

A: Once payment is confirmed and order processing is complete, the analyzer is quickly dispatched, with freight coordination ensuring timely and secure delivery to your location.

Q: Where can the G6 LEONARDO analyzer be installed and operated?

A: Designed for benchtop mounting, the G6 LEONARDO is suitable for laboratory settings, quality control departments, and research facilities requiring precise gas permeability measurements.

Q: What is the process for accessing and exporting data from the G6 LEONARDO analyzer?

A: The analyzer supports internal memory storage and offers easy data export in CSV or PDF format. Users can also perform USB backups and access real-time data through the provided PC software with remote monitoring capabilities.

Q: How does the G6 LEONARDO benefit users in laboratory film analysis?

A: With its high automation, real-time data display, and compliance with international standards, the G6 LEONARDO enhances workflow efficiency, provides reliable results, and significantly reduces testing turnaround time.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Element Analyzer C S N O H analysis in Solids Category

G4 ICARUS Series-2 Carbon-Sulfur Analyzer

G4 ICARUS Series-2 Carbon-Sulfur Analyzer

Minimum Order Quantity : 1 Unit

Application : Determination of Carbon and Sulfur in metals, alloys, ceramics, ores, and refractories

Power Supply : 230 V AC, 50/60 Hz

Features : High temperature resistance, NDIR Detection, Robust, UserFriendly Software, Automatic Data Logging

Equipment Type : CarbonSulfur Analyzer

Frequency : 50/60 Hz

G8 GALILEO Analyzer

G8 GALILEO Analyzer

Minimum Order Quantity : 1 Unit

Application : Determination of hydrogen, nitrogen, and oxygen in steel/tube materials

Power Supply : 220V AC, 50/60 Hz

Features : Autocalibration, touch operation, data storage, realtime diagnostics

Equipment Type : Metal Tube Analyzer

Frequency : 50/60 Hz

G8 GALILEO Oxygen  Nitrogen  Hydrogen Analyzer

G8 GALILEO Oxygen Nitrogen Hydrogen Analyzer

Minimum Order Quantity : 1 Unit

Application : Determination of O, N, H in ferrous and nonferrous metals, ceramics, and inorganic materials

Power Supply : 230 V AC, 50/60 Hz

Features : Automatic autoloader, integrated touch control, softwaredriven operation, highsensitivity detectors

Equipment Type : Oxygen Nitrogen Hydrogen Analyzer

Frequency : 50/60 Hz

G4 ICARUS HF Carbon And Sulfur Analyzer

G4 ICARUS HF Carbon And Sulfur Analyzer

Minimum Order Quantity : 1 Unit

Application : Material analysis

Power Supply : Electronic

Features : NDIR Detector

Equipment Type : Elemental Analyzer

Frequency : 50 Hertz (HZ)



Back to top