Glow Discharge Spectrometer

Experience the excellence of our Glow Discharge Spectrometer, expertly manufactured, supplied, and traded with over 3 years of industry experience, bringing you the finest and most advanced technology. Choose from our leading range including the GDA 650 HR Glow Discharge Spectrometer, GDA 550 HR Glow Discharge Spectrometer, GDA-Alpha Glow Discharge Spectrometer, GDA 150 HR Glow Discharge Spectrometer, and GDA 750 HR Glow Discharge Spectrometer-all designed for incomparable precision and accuracy in elemental analysis across a variety of applications. Our Glow Discharge Spectrometers boast unmatchable analytical performance with the ability to detect both trace and bulk elements efficiently, ensuring optimal sensitivity and reliability in results. They feature robust construction for long-lasting durability, intuitive controls for hassle-free operation, and cutting-edge software for comprehensive data processing. The low maintenance requirements offer cost-effective advantages, while rapid analysis saves you valuable time. This hot deal ensures limited stock availability-get yours now and experience why our Glow Discharge Spectrometers set the benchmark in quality and performance. Available for supply all across India, our spectrometers are the ultimate solution for businesses demanding accuracy and excellence in analytical instrumentation.

GDA 550 HR Glow Discharge Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Glow Discharge Spectrometer
  • Accuracy
  • Up to 1% RSD depending on element
  • Application
  • Elemental analysis of conductive and semi-conductive materials
  • Automation Grade
  • Semi-automatic/Optional fully automatic
  • Capacity
  • Suitable for single test per analysis
  • Control Mode
  • Microprocessor controlled
  • Display Type
  • TFT LCD touch display
  • Features
  • Software controlled operation, automated sample changer optional, auto-calibration
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 0.5-1.0 bar Argon (Ar)
  • Humidity
  • Up to 80% non-condensing
  • Interface Type
  • USB/Ethernet
  • Machine Weight
  • Approx. 350 kg
  • Max Height
  • Approx. 600 mm
  • Measuring Range
  • Hydrogen to Uranium (entire periodic table elements)
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • Single specimen at a time
  • Operating Voltage
  • 230 V AC
  • Port Size
  • 32 mm standard sample port
  • Power Supply
  • 230 V AC, 50/60 Hz
  • Resolution
  • High resolution, up to 2 pm (picometer)
  • Response Time
  • Typically <20 seconds for standard analysis
  • Specimen Size
  • 20 - 45 mm diameter, 2 - 10 mm thickness
  • Temperature
  • 15C to 35C operating range
  • Test Range
  • Sub-ppm to major element concentrations
  • Test Speed
  • Data acquisition up to 30 spectrums/minute
  • Test Stroke
  • Configurable, depending on specimen and cell
  • Test Width
  • Standard Cell Window 32 mm (Diameter)
  • Usage
  • Metallurgical laboratories, research, industrial quality control

GDA 650 HR Glow Discharge Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Glow Discharge Spectrometer
  • Accuracy
  • 0.1% - 1% depending on element
  • Application
  • Surface and bulk elemental analysis of metals and alloys
  • Automation Grade
  • Semi-automatic
  • Capacity
  • Up to 20 elemental channels simultaneously
  • Control Mode
  • Computer Controlled / Manual
  • Display Type
  • Digital, Computer Interface
  • Features
  • High resolution, simultaneous multi-element analysis, rapid profiling
  • Frequency
  • 50 Hz
  • Gas Pressure
  • 2-6 mbar Argon (regulated)
  • Hardness
  • N/A (Not applicable)
  • Humidity
  • Up to 80% RH non-condensing
  • Interface Type
  • USB/LAN/Ethernet
  • Machine Weight
  • 350 kg
  • Max Height
  • 600 mm
  • Measuring Range
  • ppm to % for most elements
  • Mounting Type
  • Bench top
  • Number of Specimens
  • 1 at a time (single holder)
  • Operating Voltage
  • 1000 V - 1500 V (discharge)
  • Port Size
  • 1/4 inch NPT
  • Power Supply
  • 230 V AC, 50 Hz
  • Resolution
  • 0.001% (10 ppm)
  • Response Time
  • < 1 min for single measurement
  • Specimen Size
  • 10 - 38 mm diameter, 2 - 8 mm thickness
  • Temperature
  • Room temperature (15C - 35C)
  • Test Range
  • ppm to % elemental range
  • Test Speed
  • Up to 200 mm/min
  • Test Stroke
  • Max 150 mm
  • Test Width
  • Standard: 50 mm (customizable)
  • Usage
  • Laboratory, Research and QA/QC

GDA 150 HR Glow Discharge Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Glow Discharge Spectrometer
  • Accuracy
  • Highly accurate (matrix and element specific)
  • Application
  • Depth profiling and surface analysis of conductive and coated materials
  • Automation Grade
  • Semi-automatic
  • Capacity
  • High throughput; suitable for production labs
  • Control Mode
  • Automatic & Manual
  • Display Type
  • Integrated digital display, PC based control
  • Features
  • High stability, user-friendly software, rapid analysis, long-term reliability
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 400-900 mbar (Argon)
  • Hardness
  • Depends on specimen (not an instrument parameter)
  • Humidity
  • 10% to 80% RH (non-condensing)
  • Interface Type
  • USB, Ethernet
  • Machine Weight
  • Approx. 250 kg
  • Max Height
  • Approx. 550 mm
  • Measuring Range
  • ppm to % by mass (element & matrix dependent)
  • Mounting Type
  • Bench-top
  • Number of Specimens
  • Single specimen per measurement
  • Operating Voltage
  • 230 V AC
  • Port Size
  • 25 mm / 36 mm / 51 mm
  • Power Supply
  • 230 V, 50/60 Hz, Single Phase
  • Resolution
  • High resolution: up to 5 pm wavelength discrimination
  • Response Time
  • Real-time measurement results (seconds)
  • Specimen Size
  • 10 mm to 40 mm diameter (typical)
  • Temperature
  • 15C to 35C
  • Test Range
  • Trace to major elements; ppm to % (matrix-dependent)
  • Test Speed
  • Variable, up to 0.5 mm/min
  • Test Width
  • Not Applicable (depends on specimen)
  • Usage
  • Analysis of surface, coating, and bulk compositions

GDA-Alpha Glow Discharge Spectrometer

MOQ : 1 Unit

  • Application
  • Heat Treatment, Depth Profile, Coating Analysis
  • Color
  • White
  • Features
  • Superior accuracy
  • Frequency
  • 50 Hertz (HZ)
  • Material
  • Mild Steel
  • Measuring Range
  • 190-900 nm
  • Power Supply
  • Electronic
  • Usage
  • Fixed
  • Voltage
  • 220 - 240 Volt (v)

GDA 750 HR Glow Discharge Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Glow Discharge Spectrometer
  • Accuracy
  • Better than 1% RSD (for most elements)
  • Application
  • Determination of elemental composition of metals, thin films, coatings
  • Automation Grade
  • Automatic
  • Capacity
  • Up to 400 samples/day
  • Control Mode
  • Touchscreen control panel
  • Display Type
  • 10 full-color touchscreen display
  • Features
  • Software integration, database support, high-resolution detector, environmental monitoring
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 400-800 Pa (argon atmosphere)
  • Humidity
  • 10-80% RH (non-condensing)
  • Interface Type
  • USB, Ethernet
  • Machine Weight
  • 550 kg
  • Max Height
  • 900 mm
  • Measuring Range
  • H to U; elemental depth profiles
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • Single specimen at a time
  • Operating Voltage
  • 230 V AC 10%
  • Port Size
  • Standard GD port, up to 40 mm
  • Power Supply
  • 230 V AC, 50/60 Hz
  • Resolution
  • High-resolution, sub-nanometer
  • Response Time
  • Instantaneous, measurement within seconds
  • Specimen Size
  • 5 mm to 40 mm diameter
  • Temperature
  • 10C to 35C operating range
  • Test Range
  • ppm-level to percent-level detection
  • Test Speed
  • Selectable, up to 400 analyses/hr
  • Test Stroke
  • Variable, programmable
  • Test Width
  • 5 mm to 40 mm (diameter of samples)
  • Usage
  • Laboratory metal analysis


Back to top