Optical Emission Spectrometer

Discover the exceptional quality of our Optical Emission Spectrometer, crafted by a leading manufacturer, supplier, and trader with over 3 years of experience in delivering advanced solutions for metal analysis across All India. Our range features top-performing models such as the Q8 MAGELLAN Spectrometer, Q4 Polo Metal Analysis, Q8 Magellan Optical Emission Spectrometer, Q6 NEWTON Spectrometer, and innovative FT-IR Microscopes - The future of FT-IR microscopy. Engineered for unparalleled performance, these spectrometers offer peerless accuracy, customizable analysis options, and rapid results for a variety of applications. The excellent sensitivity of our systems ensures reliable detection of trace elements, while their robust design guarantees long-lasting durability and operational efficiency. Experience new standards in precision with features such as easy-to-use interfaces, low maintenance requirements, and unmatched repeatability, making them the preferred choice in metal quality management processes. Choose our Optical Emission Spectrometer for excellent value, customizable configurations that fit your analytic needs, and top-quality assurance trusted nationwide, ensuring your operations achieve the highest standards of accuracy and reliability in every use.

Q4 Polo Metal Analysis

MOQ : 1 Unit

  • Equipment Type
  • Metal Analyzer
  • Accuracy
  • 0.05% (Depending on Material)
  • Application
  • Metal Composition Analysis
  • Automation Grade
  • Automatic
  • Capacity
  • Upto 30 kg
  • Control Mode
  • Microprocessor-Based
  • Display Type
  • LCD Digital Display
  • Features
  • Microprocessor/PCM Based, Digital Readout, Automatic Calculation
  • Frequency
  • 50 Hz
  • Hardness
  • Not Relevant
  • Humidity
  • 20-80% RH
  • Interface Type
  • RS-232/USB
  • Machine Weight
  • 59 kg
  • Measuring Range
  • 0.03%~99.99%
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • Multiple
  • Operating Voltage
  • 220V
  • Power Supply
  • 220V, 50 Hz
  • Resolution
  • 0.01%
  • Response Time
  • Instant / Real-Time
  • Specimen Size
  • Upto 180 mm in Width
  • Temperature
  • 5-40C
  • Test Range
  • 0 to 100%
  • Test Speed
  • Up to 25 mm/s
  • Test Width
  • 180 mm
  • Usage
  • Laboratory, Industry

Q4 POLO Metal Analysis

MOQ : 1 Unit

  • Equipment Type
  • Optical Emission Spectrometer
  • Accuracy
  • Depends on element, typically 0.5% relative
  • Application
  • Metal composition analysis
  • Automation Grade
  • Semi-Automatic
  • Control Mode
  • Automatic
  • Display Type
  • Color Touch Screen LCD
  • Features
  • CCD detector, Vacuum optic, Pre-installed libraries, Multi-matrix capability
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • Argon gas, 2-4 bar
  • Humidity
  • 20% to 80% (non-condensing)
  • Interface Type
  • USB, Ethernet
  • Machine Weight
  • 160 kg
  • Max Height
  • Up to 60 mm (specimen specification)
  • Measuring Range
  • ppm to high percentage (element dependent)
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • 1 (per measurement)
  • Operating Voltage
  • 230 V AC, 50/60 Hz
  • Power Supply
  • 230 V AC, 50/60 Hz
  • Resolution
  • 0.0001% (1 ppm)
  • Response Time
  • Within 60 seconds
  • Specimen Size
  • 8-40 mm diameter, up to 60 mm height
  • Temperature
  • 15C to 35C
  • Test Range
  • Multiple elements (depend on base metal)
  • Test Speed
  • 60 s/sample (typical)
  • Usage
  • Metallurgical laboratories, Foundries, Quality control

XRF Spectrometers

MOQ : 1 Unit

  • Equipment Type
  • XRF Spectrometer
  • Accuracy
  • 0.05% or better (elemental)
  • Application
  • Material Analysis, Quality Control, Environmental Testing, RoHS Screening
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • Unlimited Data Storage (via software)
  • Control Mode
  • Microprocessor Based
  • Display Type
  • LCD Touch Screen
  • Features
  • Non-destructive testing, Real-time data output, Printer support, Multi-language interface
  • Frequency
  • 50/60 Hz
  • Humidity
  • 85%RH
  • Interface Type
  • USB, RS232, LAN, WiFi
  • Machine Weight
  • 45 kg
  • Max Height
  • 150 mm (max sample height)
  • Measuring Range
  • 1 ppm to 100% (elemental)
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • 1
  • Operating Voltage
  • 220 - 240V AC
  • Port Size
  • Standard 3.5 mm
  • Power Supply
  • 220V AC, 50/60Hz
  • Resolution
  • 135 eV (Mn K)
  • Response Time
  • 1 sec to 30 sec (selectable)
  • Specimen Size
  • Customizable, max 300mm x 250mm x 150mm
  • Temperature
  • 10C to 40C
  • Test Range
  • Elemental analysis from Na (11) to U (92)
  • Test Speed
  • 0.1 - 20 mm/min
  • Test Stroke
  • Standard 40 mm
  • Test Width
  • Optional (depends on sample chamber)
  • Usage
  • Laboratory & Onsite Testing

Q4 TASMAN SERIES 2 Advanced multi-chip benchtop spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Optical Emission Spectrometer (OES)
  • Accuracy
  • High accuracy, in compliance with international OES standards
  • Application
  • Metals analysis (Fe, Al, Cu, Ni, Zn, Pb, Sn, Ti, Mg, Co, etc.)
  • Automation Grade
  • Semi-automatic
  • Capacity
  • Single sample
  • Control Mode
  • Computer-controlled via Q4 TASMAN PC software
  • Display Type
  • External computer and monitor (not part of main unit)
  • Features
  • Multi-matrix capability, automatic cleaning, touch-safe design, low argon consumption, low maintenance
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 600-900 kPa (6-9 bar) argon for optical system
  • Hardness
  • N/A (not a hardness tester)
  • Humidity
  • Max. 80% relative humidity (non-condensing)
  • Interface Type
  • USB/Ethernet interface for PC connection
  • Machine Weight
  • Approximately 95 kg
  • Max Height
  • Approx. 530 mm (instrument)
  • Measuring Range
  • Broad multi-element range (e.g. ppm to 100%)
  • Mounting Type
  • Benchtop / Tabletop
  • Number of Specimens
  • Single specimen analysis
  • Operating Voltage
  • 230 V AC
  • Port Size
  • Analysis Port: 32 mm
  • Power Supply
  • 230 V AC 10%, 50/60 Hz, 1 phase, 16A
  • Resolution
  • High spectral resolution; multi-chip CMOS detector
  • Response Time
  • Rapid analysis; typical measurement within 20-60 seconds
  • Specimen Size
  • Solid samples: thickness 3 mm, area 32 mm diameter
  • Temperature
  • +10C to +40C (operating); -10C to +50C (transport)
  • Test Range
  • ppm to percent levels, depending on element
  • Test Speed
  • Up to 60 s per analysis (typical applications)
  • Usage
  • Industrial and laboratory metal quality control

FT-IR Microscopes - The future of FT-IR microscopy

MOQ : 1 Unit

  • Equipment Type
  • FT-IR Microscope
  • Accuracy
  • Wavenumber accuracy 0.01 cm1
  • Application
  • Microspectroscopy, microanalysis, material science, forensics
  • Automation Grade
  • Fully automated mapping and focusing
  • Capacity
  • Single or multi-sample analysis
  • Control Mode
  • Touch screen and PC software
  • Display Type
  • Integrated LCD touch display
  • Features
  • Automated mapping; integrated video imaging; software control
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • N/A for standard operation
  • Humidity
  • 20-80% RH (non-condensing)
  • Interface Type
  • USB/Ethernet
  • Machine Weight
  • Approx. 20 kg (without PC)
  • Max Height
  • 400 mm overall
  • Measuring Range
  • 4000-650 cm1
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • 1-4 simultaneously
  • Operating Voltage
  • 100-240 V AC
  • Port Size
  • Standard FT-IR port adapter
  • Power Supply
  • 100-240 V, 50/60 Hz
  • Resolution
  • Spectral resolution 0.7 cm1
  • Response Time
  • < 1 sec (image display)
  • Specimen Size
  • Down to 10 m spot size
  • Temperature
  • 15-35C operating
  • Test Range
  • Spectral range: 4000-650 cm1
  • Test Speed
  • Up to 2 mm/sec
  • Usage
  • Laboratory, analytical, research

Routine FT-IR Spectrometers

MOQ : 1 Unit

  • Equipment Type
  • FT-IR Spectrometer
  • Accuracy
  • Wavelength accuracy: 0.01 cm1
  • Application
  • Qualitative and quantitative analysis of organic/inorganic samples, routine material identification, quality control
  • Automation Grade
  • Semi-automatic/Automatic
  • Control Mode
  • Fully Automatic / PC Controlled
  • Display Type
  • Digital/PC display interface
  • Features
  • Compact, user-friendly, stable opto-mechanical design, quick-change accessories, low maintenance
  • Frequency
  • 50/60 Hz
  • Humidity
  • Up to 80% RH (non-condensing)
  • Interface Type
  • USB and Ethernet (PC connection)
  • Machine Weight
  • Approximately 12 kg
  • Measuring Range
  • 4000 - 400 cm1
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • Single/Multiple (depends on selected accessory)
  • Operating Voltage
  • 100-240 V AC
  • Port Size
  • Standard sample compartment size compatible with most ATR/Transmission accessories
  • Power Supply
  • 100-240 V AC, 50/60 Hz
  • Resolution
  • Up to 0.5 cm1
  • Response Time
  • Seconds per scan (typically < 2 s/scan)
  • Specimen Size
  • Standard sample holders or ATR crystal (typically 10 mm 10 mm)
  • Temperature
  • Ambient (10C to 35C)
  • Test Range
  • 4000 - 400 cm1 (standard); optional to 7000 - 350 cm1
  • Test Speed
  • User-selectable, up to 2 spectra/sec
  • Usage
  • Routine laboratory spectroscopy, QC laboratory, research analysis

Q2 ION Metal Analysis

MOQ : 1 Unit

  • Equipment Type
  • Q2 ION Ultra Compact Metals Analyzer
  • Accuracy
  • superior accuracy
  • Application
  • Laboratory use, Analysis of Metallic Samples
  • Color
  • White Black
  • Frequency
  • 50 Hertz (HZ)
  • Power Supply
  • Electronic
  • Usage
  • Benchtop
  • Voltage
  • 220 - 240 Volt (v)

Q6 NEWTON Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Optical Emission Spectrometer
  • Accuracy
  • Conforms to International Standard Methods
  • Application
  • Metals Analysis, Quality Control, Material Verification
  • Automation Grade
  • Automatic
  • Capacity
  • Multielement measurement
  • Control Mode
  • Microprocessor Controlled
  • Display Type
  • Integrated Touchscreen Display
  • Features
  • Multi-Base; Wide Element Range; Smart Diagnostics
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 6-8 bar argon
  • Humidity
  • 10-80% RH
  • Interface Type
  • USB, Ethernet, RS232
  • Machine Weight
  • 55 kg
  • Measuring Range
  • Varies by element and material (ppm - %)
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • Single specimen analysis
  • Operating Voltage
  • 230 V
  • Port Size
  • 16 mm or 10 mm
  • Power Supply
  • 230 V AC, 50/60 Hz
  • Resolution
  • High Spectral Resolution CCD
  • Response Time
  • < 30 seconds
  • Specimen Size
  • Varies (Typical: disc, ring, rod, pipe, etc.)
  • Temperature
  • 10-35C
  • Test Range
  • ppm to % (Varies by element)
  • Test Speed
  • Up to 10 spectra/sec
  • Usage
  • Laboratory, Industrial

Q8 Magellan Optical Emission Spectrometer

MOQ : 1 Unit

  • Accuracy
  • Superior accuracy
  • Application
  • Laboratory, Industrial use
  • Color
  • White Blue
  • Frequency
  • 50 Hertz (HZ)
  • Material
  • Mild Steel
  • Power Supply
  • Electronic
  • Voltage
  • 220 - 240 Volt (v)

Icp Oes Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • ICP OES Spectrometer
  • Accuracy
  • 1% RSD
  • Application
  • Elemental Analysis in Environmental, Pharmaceutical, Metallurgy, Food & Beverage
  • Automation Grade
  • Automatic
  • Capacity
  • Simultaneous Multi-Element Analysis
  • Control Mode
  • Full Computer Control
  • Display Type
  • Digital LCD/Software Interface
  • Features
  • Dual View Optics, Automated Sample Introduction, Plasma Torch
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 0.5 MPa - 0.6 MPa
  • Humidity
  • Up to 80% RH (non-condensing)
  • Interface Type
  • USB, Ethernet
  • Machine Weight
  • 130 kg
  • Measuring Range
  • ppb (g/L) to % Level
  • Mounting Type
  • Bench Top
  • Number of Specimens
  • One at a Time
  • Operating Voltage
  • 220V AC
  • Port Size
  • Standard 15 mm for Inlet/Outlet Gas Ports
  • Power Supply
  • AC 220 V 10% , 50/60 Hz
  • Resolution
  • 0.008 nm at 200 nm
  • Response Time
  • Instantaneous Data Acquisition
  • Specimen Size
  • Liquid Sample, 10-15 mL
  • Temperature
  • 15 C - 35 C
  • Test Range
  • Trace Level to Major Elements
  • Usage
  • Professional Laboratory Use

FT-IR Research Spectrometers

MOQ : 1 Unit

  • Equipment Type
  • FT-IR Research Spectrometer
  • Accuracy
  • 0.01 cm-1
  • Application
  • Chemical analysis, material identification, quantitative analysis
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • High Throughput
  • Control Mode
  • Manual and Automatic
  • Display Type
  • LCD Digital Display
  • Features
  • High sensitivity, wide range, rapid scan, low noise
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 0.4 - 0.7 Mpa
  • Hardness
  • Robust Structure
  • Humidity
  • Up to 80% RH
  • Interface Type
  • USB, Ethernet
  • Machine Weight
  • 27 kg
  • Max Height
  • 480 mm
  • Measuring Range
  • Up to 4000 cm-1
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • 1
  • Operating Voltage
  • 220 V
  • Port Size
  • Standard 25 mm
  • Power Supply
  • 220 V AC, 50/60 Hz
  • Resolution
  • 0.5, 1, 2, 4 cm-1
  • Response Time
  • 1 Second
  • Specimen Size
  • Standard: 10 mm x 10 mm
  • Temperature
  • Room Temperature to 40C
  • Test Range
  • 4000 - 400 cm-1
  • Test Speed
  • 0.2 - 5 mm/min
  • Test Stroke
  • 100 mm
  • Test Width
  • 100 mm
  • Usage
  • Laboratory FT-IR Analysis

Q8 MAGELLAN Spectrometer

MOQ : 1 Unit

  • Equipment Type
  • Optical Emission Spectrometer
  • Accuracy
  • High analytical precision, typically RSD < 1%
  • Application
  • Metallurgical analysis for foundries, steel plants, and laboratories
  • Automation Grade
  • Semi-automatic
  • Capacity
  • Up to 49 elements simultaneously
  • Control Mode
  • PC-controlled
  • Display Type
  • Touchscreen/PC display
  • Features
  • Unique single-spark excitation, self-diagnostics, advanced software
  • Frequency
  • 50 Hz
  • Gas Pressure
  • 6-8 bar Argon (99.999%)
  • Humidity
  • Max. 80% (non-condensing)
  • Interface Type
  • USB and Ethernet interfaces
  • Machine Weight
  • Approx. 540 Kg
  • Measuring Range
  • Trace to percent levels (element dependent)
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • One at a time
  • Operating Voltage
  • 230 V AC
  • Port Size
  • Argon gas inlet (6 mm)
  • Power Supply
  • 230 V AC / 50 Hz
  • Resolution
  • High optical resolution due to photomultiplier and CCD/CMOS sensors
  • Response Time
  • Fast analysis, results within seconds
  • Specimen Size
  • Varies; disc, rectangular, and irregular shapes
  • Temperature
  • 15C to 35C
  • Usage
  • Spectrochemical analysis of metals


Back to top