S6 JAGUAR Spectrometer
S6 JAGUAR Spectrometer

S6 JAGUAR Spectrometer

MOQ : 1 Unit

S6 JAGUAR Spectrometer Specification

  • Display Type
  • Integrated Digital Display
  • Application
  • Elemental analysis in cement, mining, metals, chemicals, and geology
  • Humidity
  • 20 - 80% RH, non-condensing
  • Accuracy
  • High; typical precision <0.05% RSD
  • Interface Type
  • USB, Ethernet
  • Resolution
  • 160 eV at Mn K
  • Operating Voltage
  • 100-240 V AC
  • Temperature
  • 15C to 35C
  • Mounting Type
  • Benchtop
  • Response Time
  • Results in minutes
  • Test Range
  • Na (Sodium) to U (Uranium)
  • Power Supply
  • 100-240 V, 50/60 Hz
  • Number of Specimens
  • Multiple, batch mode capable
  • Measuring Range
  • ppm to 100%
  • Specimen Size
  • Up to 40 mm diameter
  • Frequency
  • 50/60 Hz
  • Equipment Type
  • XRF Spectrometer
  • Features
  • Compact, low-power, no water cooling, intuitive software interface, sealed sample chamber
  • Max Height
  • 125 mm (instrument)
  • Gas Pressure
  • No external gas required (air-cooled)
  • Port Size
  • Standard XRF Port
  • Automation Grade
  • Semi-automatic
  • Usage
  • Routine elemental analysis, quality control
  • Capacity
  • Single or multiple sample loading
  • Machine Weight
  • 45 kg
  • Test Speed
  • Up to 200 tests/hour
  • Test Width
  • Up to 40 mm sample size
  • Test Stroke
  • Adjustable
  • Control Mode
  • Automatic and Manual
  • Calibration
  • Factory calibrated for major oxides and elements
  • Safety
  • Fully shielded for operator safety with interlocks
  • Software Compatibility
  • Bruker TouchControl, QMatrix, and Spectra EDX
  • Dimensions
  • 45 36 35 cm (WDH)
  • X-ray Tube Power
  • 50 W
  • Tube Type
  • 50 kV X-ray tube with high excitation efficiency
  • Cooling System
  • Air-cooled, no external chiller necessary
  • Data Storage
  • Built-in memory and export via USB
  • Sample Preparation
  • Pellets, powders, pressed, fused or loose powders
  • Detector Type
  • Silicon Drift Detector (SDD)
 

S6 JAGUAR Spectrometer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 2-10 Days
  • Main Domestic Market
  • All India
 

About S6 JAGUAR Spectrometer



Experience the splendiferous S6 JAGUAR Spectrometer-a rare find for elemental analysis, now available at a monumental markdown. Boasting a 50 kV high-efficiency X-ray tube, premium Silicon Drift Detector, and a fully shielded design, this benchtop marvel assures operator safety and delivers the finest precision (<0.05% RSD). Its intuitive TouchControl software, factory calibration, and batch mode capacity make it ideal for cement, mining, metals, and geological labs. Enjoy seamless USB data exports and effortless operation-with zero water-cooling requirements. Purchase this compact, automated XRF spectrometer for unrivaled quality and value.

Unmatched Versatility and Performance

The S6 JAGUAR Spectrometer offers a compact yet powerful solution for routine elemental analysis. Featuring an air-cooled 50 kV X-ray tube, advanced Silicon Drift Detector, and adjustable parameters, this benchtop instrument excels in quality control. It is suitable for diverse samples-pellets, powders, and fused materials-and accommodates up to 40 mm specimen size. This versatile system finds application in cement plants, mining environments, metallurgy labs, and chemical facilities, with a sealed chamber for superior safety and accuracy.


Markets, Certifications, and Seamless Supply

The S6 JAGUAR Spectrometer is widely supplied throughout the main domestic market in India and is certified to meet stringent industry standards. Global export markets value its reliability, facilitated by secure charge processes and streamlined transportation logistics. We ensure consistent and safe supply to international customers, making it a dependable choice for laboratories and industries across continents. Our robust certification and support services add further value, ensuring peace of mind for every user.


FAQ's of S6 JAGUAR Spectrometer:


Q: How does the S6 JAGUAR Spectrometer ensure operator safety during use?

A: The S6 JAGUAR Spectrometer incorporates comprehensive shielding and interlock features to fully protect operators from X-ray exposure, ensuring safe daily operation in laboratory environments.

Q: What types of samples can be measured using the S6 JAGUAR Spectrometer?

A: This spectrometer supports a range of sample types, including pellets, powders (pressed, fused, or loose), and can analyze sample sizes up to 40 mm in diameter, making it adaptable to various application needs.

Q: Where can the S6 JAGUAR Spectrometer be used most effectively?

A: The instrument is designed for applications in cement production, mining exploration, metal processing, chemical labs, and geological research, delivering accurate elemental analysis in these demanding environments.

Q: What is the process for calibrating the S6 JAGUAR Spectrometer?

A: The S6 JAGUAR comes factory-calibrated for major oxides and elements, minimizing setup time. Users can perform routine calibration checks as needed for optimal precision.

Q: How can users benefit from the batch analysis capability of the S6 JAGUAR Spectrometer?

A: Batch mode allows users to analyze multiple specimens in a single run, increasing productivity and reducing turnaround time for routine quality control and research analyses.

Q: What are the benefits of its air-cooled cooling system and no external gas need?

A: The air-cooled system means no need for water chillers or external gas, simplifying installation and reducing maintenance. This makes the Spectrometer more energy-efficient and cost-effective for users.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Stationary XRF Spectrometers Category

S2 PUMA Series 2 High-end EDXRF Spectrometer

S2 PUMA Series 2 High-end EDXRF Spectrometer

Minimum Order Quantity : 1 Unit

Operating Voltage : Up to 50 kV xray tube

Resolution : <136 eV at Mn K (SDD)

Interface Type : Ethernet, USB, HDMI

Test Stroke : Not applicable (XRF noncontact)

Accuracy : Elementdependent (typically better than 0.1% for major elements)